arc

 

Syntax
arc X-axis-end, Y-axis-end, X-axis-center, Y-axis-center, Direction
 

 

Function
Generates a 2-dimensional circular arc segment.
 

Controller Returns

None

Mode
Command  

 

done? 

Syntax
done?
 

 

Function

Halts the execution of the program until the coordinated motion is completed.  

 

Controller Returns

None 

 

Mode

Run

 

 

line

 

Syntax
line X-axis-end, Y-axis-end, Z-axis-end, W-axis-end
 

 

Function

Makes a coordinated linear motion

Controller Returns
None

Mode
Command   

 

vaccel

 

Syntax
vaccel
value 

 

Function

Sets the vector acceleration of the coordinated move to value .

The value may not be modified while moving. The unit of value is in steps per sec2.

Range of Value
40,000 - 40,000,000
 

Mode
Command

 

vvel

 

Syntax
vvel value
 

 

Function

Sets the vector velocity of the coordinated move to value .

The value may not be modified while moving. The unit of value is in steps / Sec.  

Range of Value

200 – 200,000

 

Controller Returns
None
 

Mode
Command

 

 


 